Description
3 Amps DCC booster
Including adjustable power supply (15 - 24 Volt)
The DR5033 is a 3-Ampere, H-bridge DCC booster with multiple connectivity options for all available digital con-trol units. The DR5033 has a number of unique features. The booster can autonomously reverse the polarity (phase rotation) of its output if a connection error is detected on the rail that would otherwise cause a short circuit. The booster can be connected to different systems. The DR5033 has CDE (Lenz), B-BUS (Roco), L.NET-T (Intellibox) and Railsniffer (PIKO Digi1, EcOS etc.) inputs.
The booster can be configured extremely flexibly to suit your situation using L.NET LNCV programming. When connected to L.NET, the DR5033 can optionally be switched on and off by the STOP-GO buttons on the control unit or via a (configurable) switching address. The booster then reports its status to the control unit via L.NET and the load (0-100%) and the temperature of the H-bridge can be read out in degrees C via LNCV. When con-nected to L.NET, the DR5033 can monitor a configurable switching address, which can be used to reverse the polarity of the booster. Furthermore, the booster can monitor 2x2 configurable feedback addresses (2x reverse polarity on, 2x reverse polarity off) which enables a short-circuit-free reverse loop circuit to be made.
Roco Z21/z21/MultiMaus
R-BUS
L.NET
Lenz DCC CDE
TRACK-SNIFFER
H-BRIDGE
RAILCOM
18V / 3-Ampère
Automatische fase herkenning/correctie
Including adjustable power supply (15 - 24 Volt)
The DR5033 is a 3-Ampere, H-bridge DCC booster with multiple connectivity options for all available digital con-trol units. The DR5033 has a number of unique features. The booster can autonomously reverse the polarity (phase rotation) of its output if a connection error is detected on the rail that would otherwise cause a short circuit. The booster can be connected to different systems. The DR5033 has CDE (Lenz), B-BUS (Roco), L.NET-T (Intellibox) and Railsniffer (PIKO Digi1, EcOS etc.) inputs.
The booster can be configured extremely flexibly to suit your situation using L.NET LNCV programming. When connected to L.NET, the DR5033 can optionally be switched on and off by the STOP-GO buttons on the control unit or via a (configurable) switching address. The booster then reports its status to the control unit via L.NET and the load (0-100%) and the temperature of the H-bridge can be read out in degrees C via LNCV. When con-nected to L.NET, the DR5033 can monitor a configurable switching address, which can be used to reverse the polarity of the booster. Furthermore, the booster can monitor 2x2 configurable feedback addresses (2x reverse polarity on, 2x reverse polarity off) which enables a short-circuit-free reverse loop circuit to be made.
Roco Z21/z21/MultiMaus
R-BUS
L.NET
Lenz DCC CDE
TRACK-SNIFFER
H-BRIDGE
RAILCOM
18V / 3-Ampère
Automatische fase herkenning/correctie
Specifications
Data formatsDCC / Motorola
Reference data
Manufacturer’s item no.DR5033-ADJ
EAN8718375561843
ReleasedNovember 2017
ScaleNeutral
Era–
Power system–
Railway company–
Market value
Coming soon
The modellbahn·fokus market value index will in future show reference values for both available and discontinued models — transparently derived and continuously updated.
Comments from members (0)
No comments on this model yet – be the first.
Only signed-in members can write comments. Sign in now
Report an error or suggest an addition
Do you know this model better? The editors review every note.